Oneflow
Connect Oneflow to Safeguard: what it provides, how to set it up, and the frameworks it provides evidence for.
Connect Oneflow to collect digital signature evidence with automated compliance tests, switched on per workspace.
| Category | Digital Signature |
| Connect with | API token |
| What a connection produces | Automated compliance tests |
| Oneflow's guide | developer.oneflow.com |
Connect with an API token
-
In Oneflow:
- Log in to Oneflow as an admin and navigate to the Marketplace.
- Select SCIM and click Enable.
- Copy the API token that appears and store it securely; this SCIM token is what you paste into Safeguard.
The SCIM API is at https://api.oneflow.com/scim/v1 with bearer auth. Oneflow's SCIM token can also create users, update attributes and deactivate users; there is no read-only one. Enabling SCIM in the Marketplace is the same step used for Okta/Entra provisioning, so if SCIM is already enabled for your IdP, coordinate before generating or sharing a token. The general API token (Marketplace > API tokens > Custom Integration > API Tokens > + Generate a new token) is shown only once, but the Oneflow SCIM article does not say whether the SCIM token is.
Source: support.oneflow.com, developer.oneflow.com, checked 2026-10-07.
The permissions Safeguard needs:
SCIM API token. A SCIM token can also create and change users, and Oneflow has no read-only one. Safeguard only reads with it. -
On Compliance › Connectors, open Oneflow, click Connect, choose API token and fill in:
Field What to enter SCIM token Required. Stored encrypted and never shown again. -
Click Connect with token.
Frameworks
Safeguard's automated tests read Oneflow and map to the controls below. When a test passes, the result is evidence toward each control it maps to, in every framework listed. It is evidence toward a control, not proof that the control is met on its own.
| Framework | Evidence | Controls | Tests |
|---|---|---|---|
| SOC2 | Automated tests | CC6.2, CC6.3 | 2 |
| ISO/IEC 27001 | Automated tests | A.5.16, A.5.18, A.6.5 | 2 |
| HIPAA Security Rule | Automated tests | 164.308(a)(3), 164.308(a)(4) | 2 |
| PCI DSS | Automated tests | 7.2.4, 8.2.5 | 2 |
| NIST CSF 2.0 | Automated tests | PR.AA-01, PR.AA-05 | 2 |
These tests are switched on per workspace by the Safeguard team.
Related
- Digital Signature connectors
- Compliance connectors: how connecting works, card statuses and multiple accounts
- Connector setup reference: every connector in one table
- Frameworks and connectors: how connectors provide evidence for frameworks